1. Measurement object: car air conditioner 2. Sensitivity (MAX): 6gr/yr 3. Response time: instantaneous 4. Detection method: continuous, unlimited 5. Warm-up time: about 6 seconds 6. Battery life: about 50 hours under normal use 7. Probe length: 20cm 8. Working temperature: 0~52 degrees Celsius 9. Working humidity: 20% to 80%RH, no condensation 10. Power supply: 4 No. 7 batteries (not included) 11. Can detect all halogen refrigerants 12. The knob switch can adjust the sensitivity at will 13. Use high-quality corona sensor, sensitive response, longer life 14. Low power consumption design, ultra-long battery life 15. The maximum sensitivity is 6 grams/year, and the sensitivity can be adjusted in 7 levels. It can detect halogen gases such as CFCs/HCFCs/HFCs/SF-6 to meet the usage habits of different customers. 16. Ready to use, fast preheating, quick response, sound/light dual alarm 17. The freely bendable gooseneck probe can easily and quickly reach the location of the pipeline leak, and quickly and reliably locate the leak point of the refrigeration system 18. Size: 22.9x6.5x6.5cm
Can detect a variety of gases: 1. It can react with all halogen gases (including chlorine and fluorine), but it is not limited to this. Other applicable gases are as follows: CFCs: R11, R12, R500, R503, etc. HCFCs: R22, R123, R124, R502, etc. HFCS: R410, R134a, R404a, R125, R407C, etc. 2. Detection of ethylene oxide, ethanol gas, etc. used in medical equipment 3. Detection of halon gas in fire extinguishing systems 4. Detection of air conditioning, refrigeration systems and refrigerant recovery devices, etc.